A-540 | Emergency Shower & Eyewash | 04/29/10 |
B-255 | Installation of Vertical Gate Valves (Steel Pipe 14" & Larger; AC, PVC & DI Pipe 4" & Larger) | 11/02/22 |
B-271 | Saddle Outlets - 3/4" to 36" | 04/22/21 |
B-271A | Hop Tap Saddle Outlets 3/4" to 36" Diameters | 08/23/21 |
B-286B | Trench Backfill | 07/17/19 |
B-288 | Steel Flanges, 4" to 54" | 09/11/20 |
B-304 | Butt Strap Details | 09/11/20 |
B-342 | 1 1/2" Meter Installation | 04/06/22 |
B-342A | 1 1/2" Copper Service Connection | 03/20/24 |
B-344 | 2" Meter Installation | 12/21/16 |
B-344A | 2" Copper Service Connection | 09/29/22 |
B-351 | 6" x 1 - 2 1/2" Blow Off Installation (Steel Pipe) | 04/23/21 |
B-356 | 6" x 1 - 2 1/2" & 1 - 4" Fire Hydrant Installation (Steel Pipe) | 06/01/23 |
B-357 | 6" x 1 - 2 1/2" Blow-off Installation for AC, PVC & DI Pipe | 04/23/21 |
B-362 | 6" x 1 - 2 1/2" & 1 - 4" Fire Hydrant Installation for AC, PVC & DI Pipe | 06/01/23 |
B-367 | 2" Air Valve Installation | 05/29/19 |
B-407 | Thrust Block Installation for Hub-End Pipe | 05/05/22 |
B-408 | Water Pipe Installation and concrete Cap Detail for ACP, PVC & DI Pipe | 04/23/21 |
B-516 | 6" x 2 - 2 1/2" x 1 - 4" Fire Hydrant Installation (Steel Pipe) | 06/01/23 |
B-517 | 6" x 2 - 2 1/2" x 1 - 4" Fire Hydrant Installation for AC, PVC & DI Pipe | 06/01/23 |
B-533 | Telemetry Wire & Terminal | 09/11/20 |
B-561 | 4" x 1 - 2 1/2" Blow-Off Temporary End Installation (Steel) | 04/23/21 |
B-563 | Steel Pipeline - Pipe Pad or Coupling for Cast Iron Fittings | 04/23/21 |
B-568 | 6" x 1 - 2 1/2" Blow Off Temporary End Installation for AC, PVC & DI Pipe | 04/23/21 |
B-575 | Steel Pipe Casing Water Pipeline | 09/11/20 |
B-577 | Installation of Butterfly Valves | 09/11/20 |
B-578 | 3"-10" Air Vacuum & Air Release Valve Installation | 11/18/20 |
B-590 | 5/8" Meter Service Connection, 1" Copper Tubing | 04/06/22 |
B-590A | 1" Copper Service Connection | 09/29/22 |
B-591 | 1" Meter Service Connection, 1" Copper Tubing | 04/06/22 |
B-597A | Reduced Pressure Backflow Preventer Assy for 3/4" - 2" | 03/24/21 |
B-597B | Reduced Pressure Backflow Preventer Assy for 2 1/2" - 3" | 04/07/22 |
B-597C | Reduced Pressure Backflow Preventer Assy for 4" - 10" | 09/15/20 |
B-598 | 1" Air Valve Installation, 1" Copper Tubing | 05/29/19 |
B-633 | 3" Meter Installation | 04/24/24 |
B-634 | 4" Meter Installation | 04/06/22 |
B-635 | 6" Meter Installation | 04/06/22 |
B-636 | 8" Meter Installation | 04/06/22 |
B-638 | Steel Cylinder Pipe- Field Joint Details Welded & Bonded Rubber Gasket | 05/03/19 |
B-653 | 6" x 1 - 4" Blow-Off Installation - Saddle Tangent Outlet - Steel Pipe | 04/17/00 |
B-654 | 10” x 12” Detector Meter with 6” Compound Bypass | 09/08/94 |
B-656 | Locator Wire Installation | 05/03/19 |
B-657 | 4", 6", 8" or 10" Double Check Detector Assembly & Reduced Pressure Detector Assembly | 03/20/19 |
B-658 | Service Connections 1" through 4" on Water Appurtenance Lateral or Watermain 16" or Larger | 05/06/19 |
B-659 | Air Test Details | 05/06/19 |
B-660 | Test Stations: Insulated Joint and Insulated Joint at Valve | 05/03/19 |
B-661 | Thermite Weld Details | 06/19/19 |
B-662 | Test Stations: Line Current, Basic & Pipe with Casing | 05/06/19 |
B-663 | Standard Restraint Tee, Dead End, Bend for PVC C-900 & C-905 | 05/06/19 |
B-665 | Guard and Marker Posts | 05/03/19 |
B-666 | Formed Sealant Groove Detail and Typical Crack Repair | 03/01/02 |
B-668 | Valve Cap & Riser Detail | 05/03/19 |
B-932 | 4" & 6" Pressure Regulator above Ground Installation | 09/30/24 |
B-933 | 8” Pressure Regulator above Ground Installation | 09/30/24 |
B-934 | Recessed Trench Plate Detail | 05/03/19 |
B-935 | Potable Water Sample Station | 05/06/19 |
B-965 | 1" Residential Meter Service Connection 1" Copper Tubing | 04/06/22 |
B-966 | Double Check Backflow Preventer Assy for sizes 3/4" - 2" | 01/19/24 |
B-967 | Double Check Backflow Preventer Assy for sizes 2 1/2" - 3" | 09/15/20 |
B-968 | Double Check Backflow Preventer Assy for sizes 4" - 10" | 09/15/20 |
B-976 | Read Hole For Meter Vaults - Relacing A-496 | 09/15/20 |
B-977 | Typical Steel Tank Circumferential Stairway (sheet 1 of 2) | 04/16/24 |
B-978 | Typical Steel Tank Circumferential Stairway (sheet 2 of 2) | |
B-979 | Steel Tank Roof Access Platform and Hatch | 10/10/24 |
B-984 | Steel Tank Roof Hatch | 10/10/24 |
B-986 | Reduced Pressure Backflow Device Facility Intertie | 04/15/24 |
B-987 | EMWD Facility Monument Sign | 09/17/21 |
B-993 | 4" & Larger Service Connection | 04/06/22 |
B-994 | Meter Cage - Flange Mount | 05/03/19 |
B-1024 | Wellhead Pump Foundation | 01/03/23 |
B-1073 | Trench Backfill and Roadway Repair (City of Moreno Valley) | 08/23/23 |
B-1075 | Chain Link Fence | 01/09/23 |
B-1077, A & B | Meter Bank Installation with Centered Meter Boxes within Sidewalk Panels Revision | 09/17/24 |