Engineering Standards, Specifications and Drawings
Select the specification you need from the list below.
Though many of the actual specifications can be found in the Engineering Provisions area of this site, below are some other guidelines that may be helpful.
Guidelines for Booster Pump Stations, Lift Stations and Reservoirs
In addition, the following are also available:
Approved Materials List Requirements Letter (EN-194) (06/07/2022)
Approved Materials List (See Engineering Provisions)
Approved Soils Engineers List for Developers (8/19/2024)
Approved Probationary Soils Engineers List for Developers (8/19/2024)
Hot Tap Contractors (04/25/2024)
Section | Specification | Revision Date |
---|---|---|
01 | Development Services Department and Facility Design Guidelines | 10/05/2023 |
02 | Water Standard Drawings | |
03 |
Water System Specification: Detailed Provisions Provisions that comprise this specification:
| See Engineering Provisions |
04 | Sewer Standard Drawings | |
05 |
Sewer Specification – Detailed Provisions Provisions that comprise this specification:
| See Engineering Provisions |
06 | Recycled Water Standard Drawings (EMWD offsite facilities) | |
07 |
General Construction Specifications Provisions that comprise this specification:
| See Engineering Provisions |
08 | Approved Materials List | See Engineering Provisions |
09 | Recycled Water Irrigation Guidelines Mitigation Measures & CAD Standard Guideline | 06/25/2021 02/09/2021 |
10 | Recycled Water Irrigation CAD Toolbox | |
11 | Water, Sewer, and Recycled Water CAD Toolbox | |
12 | Connections to Existing Facilities AFS Toolbox |
Water Standard Drawings
For Water System Construction
- Emergency Shower & Eyewash
- Installation of Vertical Gate Valves (Steel Pipe 14" & Larger; AC, PVC & DI Pipe 4" & Larger)
- Saddle Outlets - 3/4" to 36"
- Hop Tap Saddle Outlets 3/4" to 36" Diameters
- Trench Backfill
- Steel Flanges, 4" to 54"
- Butt Strap Details
- 1 1/2" Meter Installation
- 1 1/2" Copper Service Connection
- 2" Meter Installation
- 2" Copper Service Connection
- 6" x 1 - 2 1/2" Blow Off Installation (Steel Pipe)
- 6" x 1 - 2 1/2" & 1 - 4" Fire Hydrant Installation (Steel Pipe)
- 6" x 1 - 2 1/2" Blow-off Installation for AC, PVC & DI Pipe
- 6" x 1 - 2 1/2" & 1 - 4" Fire Hydrant Installation for AC, PVC & DI Pipe
- 2" Air Valve Installation
- Thrust Block Installation for Hub-End Pipe
- Water Pipe Installation and concrete Cap Detail for ACP, PVC & DI Pipe
- 6" x 2 - 2 1/2" x 1 - 4" Fire Hydrant Installation (Steel Pipe)
- 6" x 2 - 2 1/2" x 1 - 4" Fire Hydrant Installation for AC, PVC & DI Pipe
- Telemetry Wire & Terminal
- 4" x 1 - 2 1/2" Blow-Off Temporary End Installation (Steel)
- Steel Pipeline - Pipe Pad or Coupling for Cast Iron Fittings
- 6" x 1 - 2 1/2" Blow Off Temporary End Installation for AC, PVC & DI Pipe
- Steel Pipe Casing Water Pipeline
- Installation of Butterfly Valves
- 5/8" Meter Service Connection, 1" Copper Tubing
- 1" Copper Service Connection
- 1" Meter Service Connection, 1" Copper Tubing
- Reduced Pressure Backflow Preventer Assy for 3/4" - 2"
- Reduced Pressure Backflow Preventer Assy for 2 1/2" - 3"
- Reduced Pressure Backflow Preventer Assy for 4" - 10"
- 1" Air Valve Installation, 1" Copper Tubing
- 3" Meter Installation
- 4" Meter Installation
- 6" Meter Installation
- 8" Meter Installation
- Steel Cylinder Pipe- Field Joint Details Welded & Bonded Rubber Gasket
- 6" x 1 - 4" Blow-Off Installation - Saddle Tangent Outlet - Steel Pipe
- 10” x 12” Detector Meter with 6” Compound Bypass
- Locator Wire Installation
- 4", 6", 8" or 10" Double Check Detector Assembly & Reduced Pressure Detector Assembly
- Service Connections 1" through 4" on Water Appurtenance Lateral or Watermain 16" or Larger
- Air Test Details
- Test Stations: Insulated Joint and Insulated Joint at Valve
- Thermite Weld Details
- Test Stations: Line Current, Basic & Pipe with Casing
- Standard Restraint Tee, Dead End, Bend for PVC C-900 & C-905
- Guard and Marker Posts
- Formed Sealant Groove Detail and Typical Crack Repair
- Valve Cap & Riser Detail
- 4" & 6" Pressure Regulator above Ground Installation
- 8” Pressure Regulator above Ground Installation
- Recessed Trench Plate Detail
- Potable Water Sample Station
- 1" Residential Meter Service Connection 1" Copper Tubing
- Double Check Backflow Preventer Assy for sizes 3/4" - 2"
- Double Check Backflow Preventer Assy for sizes 2 1/2" - 3"
- Double Check Backflow Preventer Assy for sizes 4" - 10"
- Read Hole For Meter Vaults - Relacing A-496
- Typical Steel Tank Circumferential Stairway (sheet 1 of 2)
- Typical Steel Tank Circumferential Stairway (sheet 2 of 2)
- Steel Tank Roof Access Platform and Hatch
- Steel Tank Roof Hatch
- EMWD Facility Monument Sign
- 4" & Larger Service Connection
- Meter Cage - Flange Mount
- 3"-10" Air Vacuum & Air Release Valve Installation
- Wellhead Pump Foundation
- Chain Link Fence
- Trench Backfill and Roadway Repair (City of Moreno Valley)
- Meter Bank Installation with Centered Meter Boxes within Sidewalk Panels Revision
- Meter Bank Installation
- Reduced Pressure Backflow Device Facility Intertie
Sewer Standard Drawings
For Sewer System Construction
- Connecting Dissimilar Sewer Pipes
- Locking Type Manhole Cover & Frame
- Reinforced Precast Shallow Manhole
- Pipe Casing (Sewer Main)
- Sewer Cleanouts
- Sewer Tree Laterals & Cleanout
- Precast Reinforced Concrete, 48" & 60" ID Manhole
- Terminus Manhole
- Manhole Cover & Frame Standard & Watertight Manholes
- Sewer Connection at Concrete Encasement
- Grease Interceptor with 24" Sampling Box
- 36" ID Sampling Manhole Precast Reinforced Concrete
- Sand / Oil Interceptor with 24" Sampling Box
- Pipe Zone Bedding for Sewer Pipe
- Trench Backfill for Sewer Pipe
- Classification of Pipe Zone Bedding for Sewer Pipe
- Sewer Lateral Connections
- Sewer Lateral
- 48" and 60" Diameter Manhole Installation for HDPE Sewer Main
- Paving Around Manholes
- Connecting Dissimilar Sewer Pipes
- Existing Sewer Manhole Median Installation
- Precast Reinforced Concrete, 60" & 72" ID Flat top
- Sewer Concrete Anchor
- Read more
Recycled Water Standard Drawings
For Recycled Water System Construction
- Metered Service Line - Recycled Water
- Installation of Vertical Gate Valves, Steel Pipe 14" & Larger & PVC, DI 4 & AC Pipe 4" & Large - Recycled Water
- 2" Recycled Meter Installation
- 2" Recycled Service Connection
- 1-1/2" Recycled Meter Service Connection
- 1" Recycled Water Meter Installation
- 3" Recycled Meter Installation
- 4" Recycled Meter Installation
- 6" Recycled Meter Installation
- 8" Recycled Meter Installation
- Agricultural Above Ground Metered Service - Recycled Water
- 4"-8" Recycled Water Blow Off