Section |
Provison |
Revision Date |
Updated Pages |
Division 0: Contracting Requirements |
00220 |
Soils Investigation |
06/06 |
|
00230 |
Construction Surveying |
10/01 |
|
Division 1: General Project Provisions |
01000 |
General Safety Requirements |
06/09 |
page numbering updated |
01026 |
Schedule of Values (this file is in MS Word format) |
02/07 |
|
01310 |
Project Control Schedule |
|
|
01380 |
Pre-construction Audio/Video Taping: Pipelines & Roadways |
10/09 |
page 1 header corrected |
01381 |
Pre-construction Audio/Video Taping: Above Ground Facilities |
|
|
01430 |
Maintenance Manual Requirements (this file is in MS Word format) |
02/07 |
|
Construction/Installation Provisions |
02050 |
Demolition and Salvage |
07/94 |
|
02051 |
Temporary Sewage Lift Station Demolition |
09/07 |
new |
02201 |
Construction Methods & Earthwork |
08/08 |
p. 19 & 20 |
02205 |
Tank Site Preparation and Base Ring Construction |
07/05 |
|
02210 |
Site Grading |
02/95 |
|
02221 |
Trenching, Backfilling, and Compacting |
05/07 |
p. 1, 2 |
02242 |
Cement Stabilized Sand Bedding/Backfill |
02/95 |
|
02252 |
Control Density Fill |
03/07 |
|
02271 |
Grouted Rip-Rap |
07/05 |
|
02433 |
Drainage Pipe: Reinforced Concrete Pipe - Storm Drain |
07/05 |
|
02444 |
Chain Link Fencing |
07/05 |
|
02505 |
Roadway Base Course |
08/92 |
|
02513 |
Asphalt Concrete Paving |
08/08 |
p. 1,2 |
02597 |
Pond Lining - Treated Soil |
02/95 |
|
02598 |
Pond Lining - Clay and Flexible Membrane |
05/93 |
|
02718 |
Installation of Water Pipeline |
05/07 |
p. 5 |
02725 |
Installation of Copper Pipe and Tubing |
05/92 |
|
02733 |
Water Well Drilling, Casting and Gravel Installation, Development, and Testing |
02/95 |
|
02761 |
Furnish & Install Vitrified Clay Sewer Pipe System |
10/02 |
|
02762 |
Furnish & Install Plastic Sewer System |
12/07 |
p.1 |
02768 |
Furnish & Install PVC Force Main |
06/98 |
|
02769 |
Furnish & Install High Density Polyethylene (HDPE) Sewer Pipe System |
10/02 |
|
02810 |
Irrigation System |
03/95 |
|
02950 |
Trees, Plants, and Ground Covers |
07/94 |
|
Division 3: Concrete Provisions |
03150 |
Formwork for Cast-in-place Concrete |
10/96 |
|
03200 |
Reinforcing |
08/99 |
|
03300 |
Cast-in-Place Concrete |
0908 |
p. 12, 19, 24, 31 |
03604 |
Casing Grouting-Annular Space |
03/95 |
|
Division 4: Masonry Provisions |
04220 |
Concrete Masonry Units |
09/08 |
p. 1, 5 |
Division 5: Metals |
05100 |
Structural Metals |
|
|
05600 |
Standards for Aluminum Work |
02/98 |
|
Division 6: Wood, Plastics, and Composites |
06100 |
Carpentry Work |
09/08 |
p. 4 |
06400 |
Plastic Lining for Concrete Structure |
04/00 |
|
Division 7: Thermal and Moisture Protection |
07920 |
Sealants and Caulking |
08/92 |
|
Division 8: Openings |
08365 |
Rolling Service Doors - Chain Operated |
|
|
08711 |
Locksets and Hardware |
06/99 |
|
Division 9: Finishes (Coatings) |
09810 |
Tape Wrap for Insulated Joints |
10/99 |
|
09811 |
Chemical Resistant Coatings |
08/92 |
|
09871 |
Coating System for Water Pumping Plants |
04/06 |
|
09872/
09873 |
Tank Painting (I-1-S , 0-1-S) |
|
|
09872 |
Interior Coating, Disinfection and Exterior Painting of a New Welded Steel Water Tank Based on all Work being Accomplished in the Field after Erection of Tank |
|
|
09873 |
Interior Coating, Disinfection and Exterior Painting of a New Welded Steel Water Tank Based on Shop Priming of Surfaces and Touch-up Defective Areas and Application of Finish Coats in Field after Erection of Tank |
|
|
09875 |
Repainting of Exterior Surfaces Based on 100% or Spot Removal of Non-Lead Based Paint and Replacement with an Alkyd/Silicone Alkyd Paint System |
|
|
09876 |
Repainting of Exterior Surfaces Based on 100% or Spot Removal of Lead Based Paint and Replacement with an Alkyd/Silicone Alkyd Paint System |
|
|
09877 |
Recoating and Disinfection of Interior Surfaces Based on 100% Removal of Existing Non-Heavy Metal Based Coating and Replacement with an Epoxy Coating System |
06/07 |
p. 12, 17, 19 |
09878 |
Recoating and Disinfection of Interior Surfaces Based On 100% Removal of Heavy Metal Based Coating and Replacement with an Epoxy Coating System |
06/06 |
p 13, 19, 21 |
09879 |
Approved Materials List for Coatings and Paints for Steel Tanks |
06/00 |
|
09892 |
Worker and Environmental Protection and Transportation and Disposal of Hazardous Wastes |
02/97 |
|
09900 |
Painting and Protective Coatings |
10/09 |
p. 15 |
09940 |
Epoxy Coating |
09/85 |
|
Division 10: Specialties |
|
There are no specialties provisions at this time. |
|
|
Division 11: Equipment Provisions |
11005 |
General Mechanical and Equipment Provisions |
10/07 |
|
11021 |
Natural Gas Engine |
10/01 |
|
11200 |
Small Submersible Sewage Lift Station with Emergency Standby Power Generation |
10/07 |
p 4 |
11210 |
Small Submersible Sewage Lift Station without Emergency Standby Power Generation |
10/07 |
p 4 |
11211 |
Centrifugal Pumps |
10/07 |
p 4 |
11240.1 |
DPS - Chemical Metering Pumps |
01/95 |
|
11240 |
Chemical Meter Pumps - General |
01/95 |
|
11241 |
Chlorination System
(On-site Sodium Hypochlorite Generation System) |
10/02 |
|
11293 |
Slide Gates |
|
|
11294 |
Stainless Steel Sluice Gates |
08/99 |
|
11343 |
Screenings Compactor |
|
|
11352 |
Scum Collection Equipment |
08/99 |
|
11931 |
Horizontal Centrifugal Water Pumps |
10/07 |
p 4 |
11936 |
Vertical Turbine Pumps |
10/07 |
p 4 |
11937 |
Deep Well Vertical Pumps |
10/07 |
p 4 |
11938 |
Progressing Cavity Pump |
10/07 |
p 4 |
Division 13: Steel Building/Water Storage Tank Provisions |
13122 |
Prefabricated Steel Building |
02/95 |
|
13311 |
Welded Steel Tanks for Water Storage |
06/00 |
|
13312 |
Bolted Steel Tanks for Water Storage |
07/00 |
|
13446 |
Valve and Gate Operations |
|
|
Division 15: Pipe/Fittings/Valves/Manholes |
15054 |
Reinforced Concrete Pipe with PVC Lining |
12/91 |
|
15057 |
Ductile Iron Water Pipe and Fittings |
05/01 |
|
15058 |
Cast Iron Fittings |
05/90 |
|
15059 |
Welded Steel Fittings |
08/85 |
|
15061 |
Steel Cylinder Water Pipe |
11/06 |
|
15064 |
Plastic (PVC) Pressure Water Pipe & Fittings |
05/02 |
|
15072 |
Asbestos-Cement Water Pipe |
11/87 |
|
15077 |
Grooved Couplings |
01/00 |
|
15081 |
Gaskets |
02/01 |
|
15089 |
Nuts & Bolts |
10/07 |
p.1 |
15101 |
Gate Valves |
01/06 |
|
15102 |
Resilient-Seated Gate Valves |
01/06 |
|
15103 |
Butterfly Valves |
01/06 |
|
15104 |
Ball Valves |
08/94 |
|
15105 |
Plug Valves |
06/07 |
p. 2 |
15108 |
Air Release Valves for Sewage Service |
12/97 |
|
15111 |
Check Valves |
02/97 |
|
15120 |
Control Valves |
03/87 |
|
15136 |
Air Valves |
03/95 |
|
15173.1 |
Propeller-Type Water Flowmeters |
05/93 |
|
15330 |
Vitrified Clay Sewer Pipe (Plain End)
(Limited to Maximum Pipe Diameter of 12”) |
05/93 |
|
15331 |
Vitrified Clay Sewer Pipe (Bell & Spigot) |
05/93 |
|
15333 |
Cast Iron & Ductile Iron Sewer Pipe |
08/85 |
|
15340 |
Manholes & Fittings |
09/99 |
|
15350 |
Sewer Pump Station, Manhole Type |
10/07 |
p 4 |
15351 |
Sewage Pump Station, Vault Type |
10/07 |
p 4 |
15385 |
Pipe Bursting |
08/99 |
|
15430 |
Emergency Eyewash/Shower Units |
09/07 |
p. 2 & 3 |
Division 16: Electrical Provisions |
16010 |
General Electrical Requirements |
02/96 |
|
16050 |
Basic Electrical Materials and Methods |
10/98 |
|
16150 |
Induction Motors |
02/94 |
|
16151 |
Vertical Hollowshaft Electric Motors |
03/96 |
|
16155 |
Solid State Reduced Voltage AC Motor Starter |
10/01 |
|
16160 |
A.C. Variable Frequency Drives |
2/06 |
|
16480 |
Main Switchboard and Motor Control Center |
05/03 |
|
16640 |
Corrosion Monitoring System for Underground Piping |
08/96 |
|
16890 |
Fiber Optic Cable and Hardware |
05/07 |
|
16891 |
Conduit/Protective Duct & Appurtenances for Future Fiber Optic Cable |
07/96 |
|
16950 |
Custom Control Panels |
02/97 |
|
Division 17: Programmable System Provisions |
17010 |
Programmable Logic Controller/Remote Terminal Unit |
06/00 |
|
Appendices |
|
Appendix A: Approved Materials List |
10/09 |
p 3 |